Rain Landing Pipe heating

 216,00 +kdv

Teklif Alın

It is a heating system for snow ice prevention in metal or PVC rain landing pipes of residential and commercial structures. You can place an order by choosing or contact our company.

Description

About the Product: For detailed information about our heating product for preventing snow and ice on roofs, you can visit our address https://www.isitmax.com/kar-eritme-cati-oluk-isitma/ . This page shows a set of heating cables in pre-prepared roof rain gutters ready for installation.

Snow and ice prevention solutions can cover a wide range of usage areas on the roofs of villas, residences, commercial buildings, public institutions or industrial buildings. Roof rain gutters from these areas appear in the following ways.

PVC Groove: In-pipe heating is carried out to ensure drainage and open drainage channels on roofs where snowfall is low but icing is seen. In systems that receive heavy snowfall and ice barriers are seen in horizontal grooves, it is recommended to consider the eaves and groove heating systems together with the heating system in rain pipes. HMax20 series heating cables are used in the system. It is enough to use a single row of cables up to 100 pipes. It is recommended to use 2 rows for larger pipes. The use of two rows of cables is not specified on our product page. You can also contact the company. Heating cables are shipped with fabricated cold tip and 3 meters cold tip connection in accordance with the selected feature. The electrician must draw energy to the cold ends of the heating cables/ cables. Hmax Heating cables are designed to operate without the need for thermostats or control panels. Regulates its own temperature (20Watt/m at 10C) according to ambient temperature. In this way, installation costs are low and consumption costs are low.

Metal Groove: Metal pipes used more often in commercial and industrial applications; can be used in the form of a single row heating cable, just like PVC grooves. Many metal pipes can have a wider diameter distance. At this point, you can contact our company. Metal grooves are heated with HMax30 series heating cables due to greater heat losses. Heating cables are fabricated in accordance with the order given and shipped with 3 meters cold tip. According to the roof rain trouser plans, the necessary supply lines are drawn with the help of an electrician.

Filter Usage: If there are normal or syonic filters on the grooves or flat terraces of industrial and commercial roofs, the filters must be taken into account when heating the rain landing pipes. Drainage and structural damage are prevented by heating around the filters and in the transition to the rain gute.

Selecting Product Variations

Pipe Material: HMax20 heating cables are used in PVC pipes and HMax30 heating cables are used in metal pipes.

Number of Rain Landings: Before heating cables are shipped, end termination and feed preparation come as fabrication. If all landings are the same size, please select or you can contact the company.

GUARANTEE

We offer 3 guarantees for our Roofmax series product.

  1. 20 Years SAFEMAX Warranty: Our Roof Heating Cables (TmaxPro, Hmax) are produced with UV resistance in design and with the engineering and raw material infrastructure required for at least 30 years of outdoor operation. In case of a manufacturing defect, product replacement (construction works belong to you) or refund (up to the invoice amount) is contractually determined in line with our SafeMax Warranty procedure. We are proud that we have not had any defective products since 1995.
  2. Thirty-day Return Guarantee: You can return the product you purchased within 30 days in case of an unopened box, wrong order, abandoned product or a problem caused by us. Special order products are not included in this scope.
  3. Best Price Guarantee: As Isitex, we are very confident in our products and prices. If you want to trust us and buy the same product from us, even though we are more expensive; please let us know where you got a better price ( info@isitmax.com ) we promise to reduce our competitor’s price to one click symbolically. If you would like more detailed information about warranties, please visit our SafeMax Page .

Note: The product you purchased is sent ready for assembly with the connections made. However, we recommend that you do not make power connections without a qualified electrician.

Note: Our RoofMax series roof heating products are suitable for use together. You can connect a different RoofMax series product to the control panel that comes with the product you purchased. Please contact us about this.

  1. Çatı Isıtma Hakkında Daha Fazla

    Commercial structures, industrial organizations and public buildings need to be heated with heating cables in rain landing pipes to relieve the snow load, prevent ice formation and icicles on the edges of the roof, and especially in order for the roof heating system to work properly.

    By placing heater cables through the rain landing pipes, the system works integrated with your existing roof heating system, draining the melting ice from the roof edge and roof groove. Snow ice detection sensors can accurately analyze the weather and predict snowfall and icing. It automatically works when needed, resulting in low energy consumption. It is disabled by the normalization of weather conditions.

    CRACKS ARE SAFE WITH ISITMAX

    Heating systems have been producing heater cables since 1995 with the knowledge and experience of carrying out many different roof types and project-specific manufacturing and application. Our heating cables are produced in Turkey with German Polymer technology and the highest manufacturing standards and prepared in accordance with the project.

    You can get detailed information specific to your project by contacting, or you can order from our packages prepared in different strengths and sizes from the product selection area, including the snow ice detection sensor and the appropriate power control board.

    Even if your rain landing pipe heating system will work perfectly in the pipe alone; we remind you that roof heating should be considered as a whole. We recommend that you also look at our products by applying heating mattresses on the edges of the roof and heating application with 30cm wide heating mattress in the grooves.

    ROOF HEATING GUARANTEE

    All heater cables used in our roofing applications are under the 10-Year Outdoor SafeMax Warranty. Our detection sensors and branded control board products are under a 5-year manufacturer’s warranty.

    Regards,

Additional information

En

100cm

Boy

100cm, 200cm

Switch The Language