Roof Edge Fringe heating

 1.405,00 +kdv

Teklif Alın

It is a heating system for snow ice prevention on the metal or membrane roof edges of residential and commercial buildings. You can place an order by choosing or contact our company.

Description

About the Product: For detailed information about our heating product for preventing snow and ice on roofs, you can visit our address https://www.isitmax.com/kar-eritme-cati-oluk-isitma/ . This page shows the pre-prepared roof edge heating kit for heating purposes, ready for installation.

Snow and ice prevention solutions can cover a wide range of usage areas on the roofs of villas, residences, commercial buildings, public institutions or industrial buildings. Roof eaves from these areas appear in the following figures.

Sloped roofs without corrugations: In regions with heavy snowfall, the snow accumulating on the roof poses a danger. Ice masses falling from adjacent structures and structures at different heights pose serious risks in terms of life and property safety. On metal clamped roofs, it is recommended to make heating with the eave length of 100 cm along with the snow trap. The collection of snow behind the eaves, which is called the hot roof, ensures that the snow accumulated in the eaves is melted and evacuated without ice.

Corrugated and low-pitched roofs: If the snow falling on residential or industrial roofs reaches the gutters over the roof and drainage cannot be provided, ice formation begins. The covered gutters and the snow that continues to come from the roof surface enter into an irreversible formation and begin to damage. The continuation of this process over and over causes the gutters on residential roofs to deform, bend, and in some cases, dislodge and fall with the weight of the snow on them. On industrial roofs, on the other hand, ice expanding in hidden creeks can cause structural damage, causing water ingress, deterioration of insulation, etc. In such cases, heating in gutters, downpipes and eaves is recommended.

Selecting Product Variations

Roofing

Our eaves heating product; It is sent with different accessories for metal roofs or shingle coatings. When the roof covering is selected, the accessories of the relevant product will be included in the box. The same heating cable ( T2MaxPro ) is used in the system. It has been designed to perform its function without loss of performance on your roof for many years with its design that is resistant to UV, high heat output and double-conductor single point feeding convenience.

Cable Quantity Selection

  • On metal roofs, you should use 8 meters of cable per m2.
  • On shingle roofs, you should use 6 meters of cable per m2.

TMaxPro and Hmax heating cables are cut in certain lengths and added to the box ready for installation together with a 3 meter cold feed end. In this way, you can place the heating cables on the edge of the roof with connection accessories as shown in the installation manual, and connect the cable ends to your supply junction boxes (your electrician will put junction boxes to connect the cables when energy is delivered to the roof).

Temperature Control: Your roof heating system should be controlled by thermostat and sensor. At this point, different control units come to the fore.

  1. Ekoline Series Control Panel : It is surface mounted. It comes with a rail type digital thermostat and temperature sensor. It is shipped ready for installation with fuses and contactors of appropriate amperage according to the installed powers. The system works when the air temperature drops below +2C, and turns off when it rises above +3C. This setting is standard by default. It can be changed easily.
  2. Proline Series Control Panel : Even if the weather is below zero degrees, there may be no icing. In this case, the heaters will work in vain. To prevent this, an extra humidity sensor is added to the temperature sensor. It is surface mounted. The rail type digital thermostat comes with a temperature sensor and an external humidity sensor. It is shipped ready for installation with fuses and contactors of appropriate amperage according to the installed powers. When the air temperature drops below +2C and the humidity sensor detects precipitation, the system starts up, and when the temperature or humidity sensor presents appropriate values together, the system shuts down. This setting is standard by default. It can be changed easily.
  3. Maxline Series Control Panel : It has the same features as Proline series control panel. The temperature regulator and sensors used in the panel are EBERLE brand. Eberle comes as a set with temperature regulator , temperature sensor , humidity sensor .

Installation: Our roof heating systems and the selections are sent ready for installation. If you see fit, you can add our in-Istanbul assembly service to your order. For out-of-town applications, it may be necessary to contact our dealers and obtain exploration and assembly information.

GUARANTEE

We offer 3 guarantees for our Roofmax series product.

  1. 20 Years SAFEMAX Warranty: Our Roof Heating Cables (TmaxPro, Hmax) are produced with UV resistance in design and with the engineering and raw material infrastructure required for at least 30 years of outdoor operation. In case of a manufacturing defect, product replacement (construction works belong to you) or refund (up to the invoice amount) is contractually determined in line with our SafeMax Warranty procedure. We are proud that we have not had any defective products since 1995.
  2. Thirty-day Return Guarantee: You can return the product you purchased within 30 days in case of an unopened box, wrong order, abandoned product or a problem caused by us. Special order products are not included in this scope.
  3. Best Price Guarantee: As Isitex, we are very confident in our products and prices. If you want to trust us and buy the same product from us, even though we are more expensive; please let us know where you got a better price ( info@isitmax.com ) we promise to reduce our competitor’s price to one click symbolically. If you would like more detailed information about warranties, please visit our SafeMax Page .

Note: You can rotate your heating mat by cutting it or remove the cable from the conveyor belt and change its location during assembly. Even if there are slight deviations in your size, you can continue to lay.

Note: Heatingx, which has been manufacturing and installing heating cables since 1995; It offers its products as a set that is very easy to lay and hassle-free. You can easily install your system yourself or with the help of an electrician.

  1. Çatı Isıtma Hakkında Daha Fazla

    Electric Roof Heating and Gutter Heating Systems

    Although our country generally has a warm and mild climate, we also encounter heavy snowfall and frost events frequently in winter. Although snow creates a pleasant impression as a natural beauty, the snowfall, the subsequent melting and freezing of the melting snow can cause significant problems on the roofs. The covering of the grooves designed for the evacuation of snow and rainwater from the roof with ice as a result of melting and freezing forms the basis of these problems.

    Problems such as melting snow waters on the roof surface seep into the attic, disrupting roof insulation, severe heat losses, regional currents in the building, corrugated-roof cover and damage to the exterior cladding are the main problems. Such unexpected situations result in very high costs. In addition to the damages that may occur on the roof surface due to icing, there are also life-threatening hazards that may occur when the grooves break due to the weight of the icicles and the stalactites break and fall at unexpected moments.

    WHAT IS AN ELECTRICAL ROOF HEATING SYSTEM?

    Roof heating systems have improved significantly in the recent past, and electric heater cables have been produced to solve all these negative situations. These cables are a highly effective and alternative material for preventing icing on the roof surface and grooves. Heater cables fixed with aluminum tapes and silicone to the area where icing will be prevented, such as the corrugated and roof surface, convert electrical energy into heat energy, preventing the formation of icing. Thus, melting snow waters freeze again, clogging the gutters and preventing the danger of stalactites. Since the water easily finds a flow route, the problem is completely solved.

    IS THE ELECTRICAL ROOF HEATING SYSTEM SAFE?

    The cables used in the electric roof heating system pose no danger, are completely safe. They are resistant to even the heaviest winter conditions. They work smoothly in all conditions. Their lifespan is quite long.

    AUTOMATIC ICING DETECTOR FOR ROOF HEATING

    The electric roof heating system, which is preferred for snow ice melting for roofs, works only when needed with its icing detector. It consists of an icing detector, humidity-temperature sensor and control box. As soon as it detects that the icing has started, the heater provides energy flow to the cable and the heating process begins. Thus, unnecessary energy consumption and expenditure are prevented. If the air temperature is very low but there is no icing on the roof, the system does not kick in. The electric roof heating system begins to work only in case the air temperature drops below zero and there is moisture, water, snow on the roof surface or groove. In short, it is enough to create the risk of icing.

    WHERE TO USE ELECTRIC ROOF HEATING SYSTEM?

    Electric roof heating systems in every city, especially our regions such as Erzurum-Kars, where winter conditions are severe and are subject to heavy snowfall and icing; it is a suitable and necessary technology for all structures including residential, commercial structure, public buildings and historical buildings. It’s not a luxury, it’s a real necessity. Its main uses are drain pipes, grooves and critical roof edges, as well as flushed roof drainage systems located on flat roofs.

    WHY SHOULD I BUILD AN ELECTRICAL ROOF HEATING SYSTEM?

    Energy saving with smart heating cables

    Standard heating cables provide constant and continuous energy, while intelligent heating cables with precise control mechanism with sensors and detectors only work as needed. This provides significant financial savings in the medium term.

    Easy installation and 100% safe operation

    The installation of the system, also called roof groove resistance, is very practical and completely safe to use. There are also practical roof heat bands placed on the roofs for defrosting purposes. Heater cable and tape can be cut to the required length and can be used in grooves without risks such as overheating or burning.

    Durable and long-lasting material

    Even when exposed to the harshest weather conditions, the UV-resistant modified polyolefin retains itself thanks to its outer sheath and offers long-lasting comfort of use.

    HOW DOES IT COST TO BUILD AN ELECTRICAL ROOF HEATING SYSTEM?

    As with all installation services, the most important factors affecting pricing in the installation of electric roof heating system are the surface area and material quality of the region to be applied. Electric roof heating systems, which are the easiest and most practical method for snow ice prevention on your groove and roof surfaces, are offered to you using the highest quality and safest materials with heating experience and technological infrastructure. Following the on-site exploration and feasibility studies to be carried out in the building where the system will be applied, the most appropriate price is determined for you. With your electric roof heating system, which is installed by the expert Heating team in a very short time; it is up to you to enjoy comfort without any problems during the entire winter months.

    As Heatmax, we spend all our energy for the peace and comfort of our customers with our technological heating solutions that make life easier.

    For the most suitable heating recommendations for your roof and electric roof heating prices, you can reach us here and easily solve your roof heating problems with our smart heating infrastructure fed by technology.

Additional information

Kablo Uzunluğu

104m/1768W, 107 mt, 10m, 113m/2100W

Kontrol Panosu

Feature-Appropriate Dashboard, I don't want a control board, Suitable for the feature Panel + Humidity Sensor

Switch The Language
    Cart
    Sohbeti Başlat
    ISITMAX A.Ş
    Merhaba,
    Roof Edge Fringe heating
    Ürünümüz ile ilgili size destek vermemi ister misiniz?